Deposition of Aerosol Particles in Bent Pipe
Hiroshi MATSUITsutomu OHHATA
Author information
JOURNAL FREE ACCESS

1989 Volume 24 Issue 3 Pages 227-235

Details
Abstract
An equation to estimate deposition fraction of aerosol particles in a bent pipe is derived and the validity is verified experimentally. The equation is obtained by assuming that the resultant acceleration of the gravity and the centrifugal force induced in the bend acts on the aerosol particles, and is found to give a relatively accurate estimation of the deposition fraction if a certain correction factor is introduced to the equation. The deposition fraction has a minimum against Reynold number, and the deposition due to centrifugal force dominates at greater Reynolds number than that at the minimum deposition fraction. On the other hand, the smaller the radius of curvature of the bend is, the larger the deposition fraction due to the centrifugal force is.