Japanese Journal of Health Physics
Online ISSN : 1884-7560
Print ISSN : 0367-6110
ISSN-L : 0367-6110
Measurements of the permeation rate of tritiated heavy water through polimeric films, and safety evaluation of protective clothing and gloves made of polymeric films
Jinzo KATOHMasafusa OHUCHI
Author information
JOURNAL FREE ACCESS

1968 Volume 3 Issue 2 Pages 288-294

Details
Abstract
In handling radioactive materials, various kinds of protective clothing made of polymeric films are employed for the protection of radioactive contamination. The permeation rate of the tritiated heavy water and its vapour through polymeric film, such as PVC, polyethylene, rubber was measured by using an ionization chamber with a vibrating reed electrometer.
On the basis of the results obtained, internal exposure of the person wearing the protective clothing is evaluated and discussed.
Content from these authors
© Japan Health Physics Society
Previous article Next article