Japanese Journal of Health Physics
Online ISSN : 1884-7560
Print ISSN : 0367-6110
ISSN-L : 0367-6110
Measurement of Static and Extremely Low Frequency Magnetic Fields around a Large Plasma Experimental Facility
Tatsuhiko UDAShugo TANAHASHIHaruo OBAYASHIHitoshi NAKATSUKAMariko ITO
Author information
JOURNAL FREE ACCESS

2000 Volume 35 Issue 1 Pages 53-63

Details
Abstract
The safety and health problems of an experimental magnetic fusion facility for a static magnetic field and variable electric and magnetic fields were considered. Static magnetic field strength was measured with a gauss meter in a large helical device (LHD) hall and outside of the 2-m concrete wall used as the radiation shield. In the case of 1.5T plasma operation, the magnetic field strength was 70mT near the cryostat and 0.05mT outside of the radiation shield. The measured magnetic strength values almost agreed with those calculated. The magnetic field strength of extremely low frequencies was measured using some commercially available monitors at the LHD site. All measured values were less than the occupational regulation levels proposed by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). Reasonable management of electromagnetic workplaces based on guidelines should be proposed for occupational safety, and active continuous survey is recommended for the facility.
Content from these authors
© Japan Health Physics Society
Previous article Next article
feedback
Top