Journal of High Temperature Society
Print ISSN : 0387-1096
Research Paper
Development of a High Response Heat Flux Gauge by Using Platinum Resistance Bulb
Masaaki MATSUURAKenichiro TAKEISHIYusuke ODA
Author information
JOURNAL FREE ACCESS

2008 Volume 34 Issue 5 Pages 234-240

Details
Abstract
A rapid-response heat flux gauge has been developed. Platinum resistance bulb of 0.4×0.4 mm area made by vacuum vapor deposition is manufactured by laser trimming on an alumina cylinder of 1.6 mm diameter and 2 mm length. Calibration test for a newly developed heat flux gauge has been conducted and fixed the temperature coefficient and the value of √ρCλ. The response of the heat flux gauge appears to be less than tens of micro seconds and the accuracy is ±10%. The heat flux distribution in the tile gap of an un-manned space shuttle has been measured with high-accuracy and wide range.
Content from these authors
© 2008 by High Temperature Society of Japan
Previous article Next article
feedback
Top