Proceedings of the Conference on Biomass Science
Online ISSN : 2423-8341
Print ISSN : 2423-8333
ISSN-L : 2423-8333
[volume title in Japanese]
Conference information

O-19 Design of the regional biomass energy system based on the effective utilization rate of resource
Takaaki FURUBAYASHIToshihiko NAKATA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 37-38

Details
Abstract

This study aims to design the regional biomass energy system considering effective utilization rate of resource and fossil fuel reduction rate. First of all, energy density maps in Koriyama city are drawn, and the demand buildings are selected from higher heat density area. As heat demands, the fuel consumption of space heating and hot water are estimated. The district heating network is designed instead of traditional individual heating system, and the total heat pipe length is 1,787 m. Woody biomass are collected from Koriyama city, and average transportation distance is 23 km. As results, the chip boiler has the largest fossil fuel reduction rate 0.85, and the gasification CHP has the smallest CO2 reduction cost 38,000 JPY/t-CO2.

Content from these authors
© 2018 The Japan Institute of Energy
Previous article Next article
feedback