Research on the Perception of Lighting Fluctuation in a Luminous Offices Environment
Tomoaki ShikakuraHiroyuki MorikawaYoshiki Nakamura
Author information
JOURNAL FREE ACCESS

2001 Volume 85 Issue 5 Pages 346-351

Details
Abstract

The non-periodic fluctuation of artificial lighting in offices was investigated to clarify the threshold at which the fluctuation is perceived. The experiments showed that fluctuation ratio of 0.92-1.06, i. e. 7% of the fluctuation, is not perceived, when the observers tried to be conscious of the fluctuation. On the other hand, under the condition of being unconscious of the fluctuation because of assigned visual tasks, the threshold has a broader range (0.8-1.3) and the value rises with the fluctuation period. It is important to dim artificial lighting without causing discomfort to office workers, and the results of this study can be used to better control of fluctuation in office lighting.