Abstract
For several standard coals, the contents of trace heavy metals were determined by use of microwave-digestion and ICP-AES. When powdery coals were shaken with an aqueous solution containing EDTA, some heavy metals, such as Mn, Pb, and Zn, were efficiently leached. When a coal fly ash was shaken with an aqueous solution of gluconic acid, As was favorably removed.