Journal of the Japan Institute of Power Electronics
Online ISSN : 1884-3239
Print ISSN : 1348-8538
ISSN-L : 1348-8538
Optimization of Compensator using Grid-impedance Estimation Method by Frequency Sweep
Yuhki KamataniTakeo NishikawaHironori TauchiTakeshi UematsuToshiyuki Zaitsu
Author information
JOURNAL FREE ACCESS

2018 Volume 44 Pages 66-72

Details
Abstract
Miniaturization and low cost of PCS (Power Conditioning System) is important for popularization of renewable energy. Especially AC reactor (ACL) is dominant in both volume and cost amount of PCS. If the ACL impedance value becomes smaller than the Grid-impedance between PCS and Grid, it is pointed out that a controllability of PCS has a risk of unstable. In this paper, we propose a control method that PCS itself estimates Grid-impedance and sets optimal control parameters after PCS installation as well. This method can be realized only by adding elements to existing configurations not change the system. As a result, it is able to contribute to downsizing and low cost of the entire PCS.
Content from these authors
© 2018 The Japan Institute of Power Electronics
Previous article Next article
feedback
Top