Intra- and inter-rater reliability of offline ultrasound measurement of ΔAPD-LH (%) for assessing pelvic floor muscle contraction
Satoko TAKAOKA, Tamami TANIGUCHI, Yasue KOBAYASHI
Author information
JOURNAL FREE ACCESS

2025 Volume 39 Issue 3 Pages 467-477

Details
Abstract

Purpose

Assessing the pelvic floor muscle power in clinical obstetrics can be difficult. The levator hiatus (LH), the anatomical opening through which the urethra, vagina, and rectum pass, can be visualized using transperineal ultrasound. During contraction of the pelvic floor muscles, the anterior–posterior diameter of the LH (APD-LH) decreases. The percentage change in APD-LH from rest to contraction (ΔAPD-LH (%)) may serve as a marker of the power of pelvic floor muscle contraction. However, its validation in postpartum women remains limited. This study aimed to evaluate the intra- and inter-rater reliability of offline ΔAPD-LH (%) measurements, based on stored ultrasound recordings.

Methods

The study enrolled 25 women aged 20 years or older, all of whom were 1–2 months postpartum following a full-term singleton vaginal delivery. After voiding, participants were positioned in lithotomy with hips and knees partially flexed. A transducer was placed perineally in the midsagittal plane to acquire a two-dimensional (2D) image encompassing the symphysis pubis, urethra, vagina, and pelvic floor muscles. Video recordings were captured during rest, pelvic floor muscle contraction, and subsequent relaxation. Examiner A measured APD-LH at rest and during contraction using the video and calculated ΔAPD-LH (%) with the formula (APD-LH at rest − APD-LH during contraction)/APD-LH at rest × 100. To determine intrarater reliability, Examiner A repeated the measurements on a separate day. For inter-rater reliability, Examiner B independently measured APD-LH and calculated ΔAPD-LH (%) from the same video following the identical procedure. Reliability was evaluated using Bland–Altman plots and the intraclass correlation coefficient (ICC).

Results

On average, APD-LH decreased by 22% during muscle contraction in assessments by both examiners. The ICC (1.1) of ΔAPD-LH (%) for intrarater reliability was 0.97 (95% CI, 0.94–0.98). The ICC (2.1) for inter-rater reliability was 0.91 (95% CI, 0.81–0.96). Bland–Altman plots for both intra- and inter-rater reliability of ΔAPD-LH (%) showed randomly scattered data points. The mean difference in ΔAPD-LH (%) between the Examiner A's two measurements was 0.11 (95% CI, −0.77–0.99) and between Examiners A and B was 0.07 (95% CI, −1.57–1.71). Both CIs included zero, indicating no fixed error. Additionally, no proportional error was observed, as no systematic relationship between measurement differences and means was evident in the Bland–Altman analysis.

Conclusion

ΔAPD-LH (%) demonstrated excellent intra- and inter-rater reliability. No fixed or proportional errors were identified within or between raters. These findings suggest that ΔAPD-LH (%) is a dependable parameter for assessing pelvic floor muscle function in postpartum women.