Abstract
We report single incision laparoscopic surgery using am E・Z access®applied on the top of lap-protector®using in children. We reviewed of 17 patients:Simple Ovarian cyst, 3;acute appendicitis, 7; interval appendectomy, 4;intussuscepation, 2;mesenteric cyst, 1.
2 cases of appendiceal mass and interval appendectomy added 5mm trocers to right upper and left lower abdominal. One of perforation of appendicitis added 5mm trocer to right upper abdominal. All casers did not open surgery.
Postoperative complication in one wound infection due to accidental removal lap protector in acute appendectomy operation, and one transient ileus after operation of appendiceal mass.
Single incision laparoscopic surgery using am E・Z access®applied to a lap protector®provided lap protector®of the wound margin with airtightness and improved stability trocers. E・Z access®was a very useful device for single incision laparoscopic surgery in children.