Lessons Learned from an Erroneous Surgery : Inversely Implanted Apicoaortic Valved Conduit
Takahiro SoumaShuichiro Takanashi
Author information
JOURNAL FREE ACCESS

2015 Volume 44 Issue 6 Pages 313-317

Details
Abstract
A 62-year-old woman with severe aortic stenosis underwent apicoaortic bypass grafting. The graft was implanted inversely at first ; on the next day, it was re-implanted in the right direction. She recovered once from heart failure ; however, on postoperative day (POD) 74, she died from respiratory failure. On POD 16, an in-house multidisciplinary investigatory commission reviewed the human factors that had led to the surgical error. Throughout the investigation, we provided relevant information about the event and explanations. We presented our apologies the patient's family and offered to compensate them for their losses.
Content from these authors
© 2015 The Japanese Society for Cardiovascular Surgery
Previous article Next article