Japanese Journal of Cardiovascular Surgery
Online ISSN : 1883-4108
Print ISSN : 0285-1474
ISSN-L : 0285-1474
A Case of Blow-Out Type Cardiac Rupture after Acute Myocardial Infarction
Motohiko GodaKiyotaka ImotoShinichi SuzukiKeiji UchidaKensuke KobayashiKoichiro DateToshiki HatsuneMakoto OkiyamaMakoto Kato
Author information
Keywords: GRF glue
JOURNAL FREE ACCESS

2007 Volume 36 Issue 5 Pages 269-272

Details
Abstract
A 83-year-old woman suffered pulseless-electrical-activity (PEA) because of cardiac tamponade after acute myocardial infarction with blow-out type cardiac rupture. Immediately median sternotomy was performed and active bleeding from the postero-lateral wall was found. It was impossible to stop bleeding only by putting pressure on the aperture of the myocardium with a piece of TachoComb coated with gelatin-resorcinol-formaldehyde (GRF) glue, however, the chemical action of GRF glue made the delicate myocardium after acute infarction stronger and we managed to stop that bleeding with mattress sutures that had initially seemed to be impossible. She was discharged on POD 103 uneventfully. We think this is a useful and safe operation procedure for blow-out type cardiac rupture.
Content from these authors
© The Japanese Society for Cardiovascular Surgery
Previous article Next article
feedback
Top