The Journal of the Japanese Society for Dental Materials and Devices
Online ISSN : 2188-4188
Print ISSN : 0286-5858
ISSN-L : 0286-5858
Original Article
Molten Titanium Flow in U-type Cavity
Kouichi WATANABESeigo OKAWAMitsugu KANATANISyuji NAKANOOsamu MIYAKAWAMasayoshi KOBAYASHI
Author information
JOURNAL FREE ACCESS

1996 Volume 15 Issue 6 Pages 532-539

Details
Abstract
By combining information from X-ray transparency and from molten titanium flow, the casting process in a U-type cavity simulating crown section was investigated under several conditions, such as type of casting machine or sprue diameter.Despite the machine type, centrifugal(CT)or two-chamber pressure(PR)machine, jet flow and F type filling were observed in the occlusal area.The flow pattern in the axial area, however, was controlled by the main body force of each casting machine;it was the B type for PR and the F type for CT.Major factors related to internal defects were sprue diameter for PR and sprue-attachment position and angle for CT.
Content from these authors
© 1996 The Japanese Society for Dental Materials and Devices