Journal of Japan Endodontic Association
Online ISSN : 2432-4485
Print ISSN : 0389-5238
Measurement of Aerial Bacteria and Dust Particles in the Dental Office
―Method of Sterilization and Disinfection in the Dental Office PartⅤ―
MASAHIRO TAGUCHI
Author information
JOURNAL FREE ACCESS

1992 Volume 13 Issue 2 Pages 232-238

Details
Abstract

  In dental treatments like extractions, implants, another surgeries, and periodontic and endodontic treatments where bleedig is present, contamination by aerial bacterias or dust particles of the environment is possible.

  In dental office there are many people coming in or leaving, patients; dental technicians, dental material salesmen, medicine salesmen, etc., and all of them bring a lot of aerial bacterias and dust particles from other places. Therefore, we must keep clean our dental office every moment.

  This time, I have taken the measurement of aerial bacteria and dust particles with the Membran Filter Method and the Laser Particles Counter after complete cleaning of the dental office using the home-use air cleaner.

  The results proved that the place was as clean as the Clean area.

Content from these authors
© 1992 Japan Endodontic Association
Previous article Next article
feedback