1971 Volume 26 Issue 5 Pages 434-437
The amount of uranium in the daily diet and human urine was measured by means of solid fluorimetry and the accuracy of this test was established.
Recovery of the dietary uranium was 52.61±4.34% at the 95% confidence level. As the coefficient of variation was small, it was concluded that this method can be used for the measurement of dietary uranium.