The Japanese Journal of Jaw Deformities
Online ISSN : 1884-5045
Print ISSN : 0916-7048
ISSN-L : 0916-7048
Original Articles
Postoperative Stability in Two-Jaw Osteotomy using Bioabsorptive Mini-Plates
SAYAKA YOSHIBATATSUO SHIROTATETSUTARO YAMAGUCHIMAKIKO ATARASHIYUUJI KURIHARAKOUTARO MAKISATORU SHINTANI
Author information
JOURNAL FREE ACCESS

2013 Volume 23 Issue 1 Pages 1-7

Details
Abstract
In this study, we evaluated the usefulness of bioabsorbable poly-L-lactide (PLLA) mini-plates for bone fixation after Le Fort I osteotomy and bilateral sagittal split osteotomy (SSRO). The subjects were 19 patients, who received two-jaw surgery using titanium and PLLA mini-plates. Lateral cephalograms were taken before surgery (T1), immediately after surgery (T2), and more than six months after surgery (T3). Changes in the measurement points were statistically analyzed. There was no statistical difference in the postoperative skeletal difference between the two groups. The post-operative stability of PLLA mini-plates is comparable to that of titanium mini-plates. PLLA mini-plates are considered to be clinically useful.
Content from these authors
© 2013 Japanese Society for Jaw Deformities
Next article