Abstract
In order to remove polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in exhaust from refuse incineration plants, the treatment of the gases by using a fabric filter with activated carbon injection is available as one of the applicable methods. This method using a fabric filter with activated carbon enabled efficient removal of PCDDs/PCDFs in operating plant. In particular, the concentration of PCDDs/PCDFs was successfully reduced to 0.1ng/Nm3-TEQ.