Japanese Journal of Magnetic Resonance in Medicine
Online ISSN : 2434-0499
Print ISSN : 0914-9457

This article has now been updated. Please use the final version.

Perfusion Imaging using Arterial Spin Labeling (ASL)
Yasuhiro FUJIWARAShota ISHIDAHirohiko KIMURA
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 2020-1719

Details
Abstract

 Arterial spin labeling (ASL) is a method for evaluating perfusion that uses magnetically labeled arterial blood water as an endogenous tracer. Although research and technical development have been conducted for a long time, introduction of ASL into clinical practice has been delayed because of its low signal-to-noise ratio (SNR). In recent years, advances in the pulse sequence and hardware, such as high static magnetic fields and high-sensitivity phased array coils, have made it possible to obtain high-SNR ASL images in a clinically acceptable time. In this regard, a consensus paper proposed simple and standard usage, including recommended techniques and parameters, to obtain a consistent image quality. Major MR manufacturers offered ASL pulse sequences based on this study. Hence, ASL has been used in clinical practice, and the effectiveness in measuring perfusion using ASL has been reported for the diagnosis of various neurological disorders. This article will review the technique for perfusion measurement and quantification and the recent technical progress in ASL.

Content from these authors
© 2020 Japanese Society for Magnetic Resonance in Medicine
feedback
Top