Japanese Journal of Physiological Anthropology
Online ISSN : 2432-0986
Print ISSN : 1342-3215
Originals
VALIDITY OF EQUATIONS FOR ESTIMATING PHYSICAL ACTIVITY INTENSITY BY THE ACTIGRAPH ACCELEROMETER IN JAPANESE INDIVIDUALS
Shunsuke GOTOKazuki OHBAAyako MORIKAWANaoyuki EBINE
Author information
JOURNAL FREE ACCESS

2020 Volume 25 Issue 4 Pages 61-77

Details
Abstract

The ActiGraph accelerometer is one of the most widely used motion sensor detectors in research. However, its applicability in Japanese has not been fully clarified. Therefore, the purpose of this study was to investigate the validity of equations for estimating physical activity intensity by the ActiGraph in Japanese. The subjects wore the ActiGraph wGT3X-BT on their waist and wrist during walking, running, and activities of daily living to assess the intensity of their physical activities. The results suggest that when worn on the waist, the ActiGraph provided the best estimation when used with Crouter’s equation. When worn on the wrist, it could not accurately estimate the intensities of the subjects’ physical activities.