Japanese Journal of Hospital Pharmacy
Online ISSN : 2185-9477
Print ISSN : 0389-9098
ISSN-L : 0389-9098
A Comparison of Microbial Contamination of Intravenous Hyperalimentaion Fluids Prepared in a Clean Booth and in the Nurse Station
TAKANORI HAYAZAKISUSUMU SANADASYUNSUKE KURONO
Author information
JOURNAL FREE ACCESS

1992 Volume 18 Issue 1 Pages 111-119

Details
Abstract
Effects to improve the quality of medical care have meant that increasingly intravenous hyperalimentation fluids (IVH) are being prepared by hospital pharmacists in clean booth or clean benches. Neverthess, there are still many places where IVH are being prepared in the nurse stations or by hospital workers other than a pharmacist. In this study, we prepared IVH under both conditions and compared the microbial contamination of each solutions. We demonstrated that if the proper methods are followed it is possible to prepare the solution free from contamination even in the ward.
Content from these authors
© Japanese Society of Pharmaceutical Health Care and Sciences
Previous article
feedback
Top