Japanese Journal of Hospital Pharmacy
Online ISSN : 2185-9477
Print ISSN : 0389-9098
ISSN-L : 0389-9098
Studies on Hospital Pharmaceutical Manufacturing (VII)
The Revision of Package Insert of 1% Methylene Blue Injection on the Basis of Clinical Need
MOEMI SAITOMACHIKO WATANABEHIROSHI OGATAKIYOTO EDO
Author information
JOURNAL FREE ACCESS

2000 Volume 26 Issue 4 Pages 454-466

Details
Abstract
One percentage Methylene Blue (MB) injection prepared in our hospital pharmacy has been used at concentrations of 0.05% and 0.25% for the treatment for methemoglobinemia and septic shock. In order to provide more information on “the package insert” which we have been making since 1996, we performed a pH variation test using a 1% MB injection and a stability test for 0.05% and 0.25% MB injections.
The changes in MB absorbance were monitored by the UV spectrometry method. No significant changes in MB absorbance were observed either at room temperature and 40°C at 1000 Lux fluorescent light or in darkness for 48 hours, under 0.05% or 0.25% MB injection conditions. Based on these results, we were able to increase the amount of information regarding the pH variation tests and stability tests on our package insert.
Content from these authors
© Japanese Society of Pharmaceutical Health Care and Sciences
Previous article
feedback
Top