Japanese Journal of Radiation Safety Management
Online ISSN : 1884-9512
Print ISSN : 1347-1503
ISSN-L : 1347-1503
Application of the small OSL elements to the ring type dosemeter
Hideaki MIYAUCHIHiroshi YOSHITOMIYoshitaka SATOFumiaki TAKAHASHIHaruo TACHIBANAIkuo KOBAYASHIAkifumi SUZUKI
Author information
JOURNAL FREE ACCESS

2013 Volume 12 Issue 1 Pages 41-45

Details
Abstract
  In the Japan Atomic Energy Agency (JAEA), exposures doses to fingertips can be significant in radiological decontamination at the facilities with mixture fields of beta and gamma (X) rays. The radiation doses to fingertips have been measured by ring type dosemeters equipped with thermoluminescence dosemeters (TLD) in JAEA. We applied small Optically Stimulated Luminescence (OSL) elements to the ring type dosemeter, which has the advantages in the use for long term and repeating in dose measurements comparing to the TLDs. The dose evaluation method with the new ring type dosemeters was established with studies on the characteristic of the OSL dosemeters by irradiation examinations and Monte Carlo simulations. In this report, we introduce the outline and the dose evaluation method of the new ring type dosemeter which we applied.
Content from these authors
© 2013 Japanese Society of Radiation Safety Managenent
Previous article Next article
feedback