Japanese Journal of Radiological Technology
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
Clinical Technologies
Study of Heart Region of Interest Setting Method in the Hepatic Functional Reserve Index of 99mTc-Diethylenetriamine Pentaacetic Acid-Galactosyl Human Serum Albumin
Yoshimasa TakahashiMasayuki AkiyamaToru SaitouKyoichi KatoYasuo Nakazawa
Author information
JOURNAL FREE ACCESS

2014 Volume 70 Issue 8 Pages 799-804

Details
Abstract

In this study we analyzed the influence of region of interest (ROI) selection on the uptake ratio of the liver to the liver plus heart at 15 min (LHL15) during 99mTc-galactosyl human serum albumin (GSA) scintigraphy and determined the optimal ROI by evaluating the individual effects of different ROIs in the heart on LHL15. Twenty patients were randomly selected from those who had undergone 99mTc-GSA scintigraphy GSA between April 2008 and June 2009. The liver body (L/B) ratio, liver uptake 15 min (LU15), and LHL15 were analyzed and compared among the following ROIs: entire heart, both ventricles, right ventricle, and left ventricle. There were significant differences in the L/B ratio and LU15 values among the different ROIs. However, LHL15 showed a tendency to shift toward a normal value when the size of the ROI was small (only the right or left ventricle), resulting in a lack of distinction between normal and abnormal LHL15 values. Furthermore, setting the entire heart as the ROI was difficult and reproducibility was low. Our results suggest that the use of both ventricles as the ROI provides optimal LHL15 values during 99mTc-GSA scintigraphy.

Content from these authors
© 2014 Japanese Society of Radiological Technology
Previous article Next article
feedback
Top