The Journal of the Japanese Society of Clinical Cytology
Online ISSN : 1882-7233
Print ISSN : 0387-1193
ISSN-L : 0387-1193
Original Articles
Assessment of the adequacy of endometrial liquid-based cytology with the Beckton Dickinson SurePathTM method
Azusa HANADA, Yasuo HIRAI, Kaoruko OKADA, Yuuko KIMURA, Yoshika AKIZAWA, Yoji NAGASHIMA, Yoshiaki NORIMATSU, Kenji YANOH, Ken ISHITANI, Hideo MATSUI
Author information
JOURNAL FREE ACCESS

2015 Volume 54 Issue 6 Pages 351-357

Details
Abstract
Objective : The aim of this study was to assess the adequacy of endometrial liquid-based cytology using the Beckton Dickinson SurePathTM method.
Study Design : A total of 1,097 endometrial samples were analyzed. The samples used for histological examination and cytological tests using conventional and SurePathTM methods, were collected simultaneously.
Results : The sensitivity of the samples containing more than 10 cell clumps of more than 50 cells was significantly higher than those containing less than 10 cell clumps (78.7% vs. 36.8%). In contrast, as for the difference between clumps having more than 50 cells and having more than 30 cells, no significant difference was detected in the sensitivity, specificity, PPV, or NPV.
Conclusion : In the SurePathTM specimens, the total number of clumps including small clumps is the most critical factor on which adequacy depends. Our study suggested that specimens containing more than 10 cell-clumps of more than 30 cells are adequate for examination with SurePathTM.
Content from these authors
© 2015 The Japanese Society of Clinical Cytology
Next article
feedback
Top