Precision measurement for section of drill helical flute
—Improvement of measurement accuracy by error compensation—
Yanping PENGHiroyuki KUMEHARAWei ZHANGHiroshi SUDA
Author information
JOURNAL FREE ACCESS

2007 Volume 73 Issue 1 Pages 129-133

Details
Abstract
A measuring system of drill geometry parameters has been proposed in the previous report. The system is based on laser displacement sensor, slide and rotary tables. Different types of errors may occur while collecting the coordinate data of the drill geometry parameters. This paper describes the calibration of the measuring system for estimating grinding parameters and geometry parameters of the drill point. The calibration procedure, calibration method and error correction method are proposed in this paper. To develop a practical apparatus of the measurement system all setup errors have been considered and measured and as the database they are preserved. Thus, the error can be corrected automatically according to the measuring position. The measured data agrees well with the designed values. It was proved theoretically that the accuracy achieved by this method is enough for the measurement of the drill.
Content from these authors
© 2007 The Japan Society for Precision Engineering