Journal of the Japan Society for Precision Engineering
Online ISSN : 1882-675X
Print ISSN : 0912-0289
ISSN-L : 0912-0289
Paper
Measurement Method of Eyelid Pressure Distribution Using Thin Film Coating on Contact Lenses
-1st report : Film Thickness Dependence in the Abrasive Test on Sucrose Coating-
Takeshi HATSUZAWAKentaro TAKAO
Author information
JOURNAL FREE ACCESS

2020 Volume 86 Issue 7 Pages 558-561

Details
Abstract

Distribution measurement of eyelid pressure is an important technology for diagnosis and treatment on corneal disorders, dry eyes etc. The measurement methods are limited because of the eyeball surface curvature, as well as the eyelid pressure itself is fairly small ranging from 10 to 30 mmHg. So far, MEMS fabricated contact lenses and strip pressure sensors have been proposed, however, distribution measurement are impossible except an average or a local pressure. In this study, we propose a new method for the pressure and abrasive distribution measurement, in which, a color film coated contact lens works as a sensing device for the film thickness decrease due to blinking. In the first report, we experimentally evaluated thickness reduction characteristics of sucrose films, using a newly developed friction tester. Experimental results show its sufficient potential as a sensing material for eyelid pressure measurement.

Content from these authors
© 2020 The Japan Society for Precision Engineering
Previous article Next article
feedback
Top