Journal of the Japan Society for Precision Engineering
Online ISSN : 1882-675X
Print ISSN : 0912-0289
ISSN-L : 0912-0289
Piezoelectric-driven Turntable with High Positioning Accuracy (2nd Report)
Reliability of Piezoelectric-driven Turntable
Toru TOJOKazuyoshi SUGIHARASusumu SAITO
Author information
JOURNAL FREE ACCESS

1989 Volume 55 Issue 12 Pages 2181-2186

Details
Abstract
In the 1st report, it has been shown that a newly developed piezoelectric-driven turntable moved by the “inchworm” function is capable of positioning accuracy with less than 4.8×10-7 rad (0.1 arcsec) for a range of π/2. And it also has the following advantages ; (1) operable in a vacuum environment, (2) non-magnetic material construction, (3) small heat generation, (4) compactness. However, there were some problems for practical use, such as the reliability of the piezoelectric actuator and wear of the clamping parts. In the present report, it has been shown that the developed piezoelectric-driven turntable can be used continuously for a long period of time, over 2 000 hrs, by improving the piezoelectric actuator and by appropriate clamp clearance selection.
Content from these authors
© by The Japan Society for Precision Engineering
Previous article Next article
feedback
Top