MACRO REVIEW
Online ISSN : 1884-2496
Print ISSN : 0915-0560
ISSN-L : 0915-0560
An experimental study of direct-contact heat transfer of ice formation
Raksit ThitipatanapongBundit LimmeechokchaiSupachart Chungpaibulpatana
Author information
JOURNAL FREE ACCESS

2003 Volume 16 Issue 1 Pages 195-199

Details
Abstract

An alternative direct-contact heat transfer in ice formations has been proven for efficient ice production method of thermal storage for cooling purpose. It maintains constant thermal resistance during ice formation process, which has better performance than conventional indirect ice formation method. In this study, the experimental investigation in ice formation on pilot scale direct-contact heat exchanger was conducted with capacity of ice formation of 1.5 refrigeration ton. The HFC-134a has been used as contact refrigerant with a mass flux in the direct-contact column varying from 0.98 to 2.19kg/m2s. The results show that water was frozen as a porous small grain slurry at 8.5°C resulting in higher refrigerator's coefficient of perfermance (COP) than conventional ice produciton systems.

Content from these authors
© JAPAN MACRO-ENGINEERS SOCIETY
Previous article Next article
feedback
Top