1985 Volume 9 Issue 2 Pages 263-266
A new circuit element with coaxial structure is proposed which is constructed by using two magnetic pipes. In this element, the inner pipe and the outer pipe are connected in series electrically, and current flows through both pipes. The element exhibits a number of interesting operating characteristics. There is a remarkable skin effect at the commercial frequency and appearance of unbalanced impedance between inner and outer pipe.
In this paper, the magnetic coaxial pipe is shown to be useful as a heating element of pipe transportation for high viscous liquid by utilizing its remarkable skin effect. The voltage drop on the outside of outer pipe is very small, because the impedance of outer pipe is much smaller than that of the inner pipe. A pipe heating system with high power factor and sufficient heat generation therefore can be constructed with the magnetic coaxial pipe.