Overlapped Double-Layer Micromesh Stents for Giant Extracranial Internal Carotid Artery Aneurysm
Tomoaki MurakamiShingo ToyotaMotohide TakaharaKazuhiro TouharaTatsuya HagiokaYuhei HoshikumaTakamune AchihaTakeshi ShimizuMaki KobayashiHaruhiko Kishima
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: cr.2023-0020

Details
Abstract

Objective: Extracranial internal carotid artery aneurysms (ECAAs) are rare. We herein describe a case of overlapped stenting with two double-layer micromesh stents for a giant ECAA.

Case Presentation: A 73-year-old man presented to our hospital with an enlarged right posterior cervical mass. A right internal carotid artery (ICA) angiogram revealed a giant aneurysm of 50 × 60 mm. We chose a carotid double-layer micromesh stent for stenting. With the patient under general anesthesia, the first double-layer micromesh stent (CASPER Rx, 10 × 30 mm; Terumo, Tokyo, Japan) was deployed between the ICA distal to the aneurysm and the common carotid artery (CCA). The second stent was also deployed from a site more proximal than the first one. Ten coils were then placed from a microcatheter that had been placed in the aneurysm. A right CCA angiogram after the procedure revealed a flow-diversion effect for the aneurysm. The patient was discharged with no complications. At the 6-month follow-up angiogram, blood flow into the aneurysm had completely disappeared.

Conclusion: A flow-diversion effect using overlapped double-layer micromesh stents can result in thrombosis and healing of giant ECAAs.