Expansion of Stent and Lumen Diameters on Follow-up after Carotid Artery Stenting in Patients with Carotid Artery Stenosis
Kenta FujimotoHiroyuki HashimotoMitsuhisa NishiguchiToshitaka InuiNaoki TaniKaoru HoriuchiMegumi ChataniRyuta MatsuokaTakahide YaegakiIchiro NakagawaHiroyuki Nakase
Author information
JOURNAL OPEN ACCESS Advance online publication

Article ID: oa.2016-0038

Details
Abstract

Purpose: We examined postoperative stent and lumen expansions after carotid artery stenting (CAS) in patients with carotid artery stenosis. Furthermore, we investigated factors influencing the stent and lumen expansions in a follow-up period.

Subjects: 134 cases (128 patients) who underwent CAS and performed follow-up cerebral angiography 12 months after CAS were enrolled into this study. The stenosis rate based on the stent and lumen diameters on follow-up angiography as a percentage of that immediately after CAS was evaluated.

Results: Both the stent and lumen diameters were significantly dilated 12 months after CAS (p <0.001). There were no significant stent-type-related differences in the stent expansion rate. In the symptomatic stenosis group, this expansion rate was significantly higher than in the asymptomatic stenosis group (p = 0.02). With respect to the presence or absence of a high signal intensity on time of flight (TOF) magnetic resonance (MR) images, the stent expansion rate was significantly higher in the high signal intensity group (p = 0.006). In patients with a plaque/sternocleidomastoid muscle signal intensity ratio of ≥1.50 on plaque images, it was significantly higher than in those with a value of <1.50 (p = 0.006). However, there were no significant differences in the lumen expansion rate among the groups.

Conclusion: Both the stent and vascular lumen were dilated 12 months after CAS. Plaque fragility influenced the stent expansion rate; however, there were no significant factor-related differences in the vascular lumen expansion rate.

Content from these authors
© 2016 The Japanese Society for Neuroendovascular Therapy

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/