Journal of Nuclear Science and Technology
Online ISSN : 1881-1248
Print ISSN : 0022-3131
Evaluation of Dosimetry Film by Neutron Activation and X-Ray Fluorescence
Dick DUFFEYW. L. BECKG. I. GLEASONP. F. WIGGINS
Author information
JOURNAL FREE ACCESS

1979 Volume 16 Issue 2 Pages 89-94

Details
Abstract

Photographic film was exposed to γ-rays from 226Ra and 60Co to levels of 5 mR to 5, 000 R. Measurements of the Ag in the developed films by both (a) activation with neutrons from 252Cf and counting 110Ag (half life 24.4 sec) and (b) X-ray fluorescence correlated with the known exposures. In the lower ranges conventional optical density measure-ments were made, and the correlation with the activation and X-ray methods was good.

Content from these authors

This article cannot obtain the latest cited-by information.

© the Atomic Energy Society of Japan
Previous article Next article
feedback
Top