Abstract
The low and high power core uncovery patterns were observed in the high-pressure quasi-steady core uncovery experiments in a 25-rod bundle. The boundary between the two patterns was obtained in the experiments. The difference of two patterns was considered to be due to the slug-annular transition below the dryout points. The Osakabe's slug-annular transition model was the good boundary between the two patterns.
The small break loss-of-coolant accident (LOCA) experiments were conducted by using the integral experimental facility with the 1, 168-rod core. The transient core uncovery pattern was expected as the low power core uncovery pattern based on the quasisteady experiments mentioned above. The transient core uncovery patterns were classified into the boiloff and hydraulic core uncovery. In the boiloff core uncovery, the dryout points were controlled with the mixture level like the quasi-steady state. In the hydraulic core uncovery, the dryout points were not controlled with the mixture level alone, and the multi-dimensional dryout process in the core and the relatively high heat transfer above the dryout points were observed. It was considered that a part of water was remained above the dryout points due to the rapid depression of core liquid level.