Journal of Power and Energy Systems
Online ISSN : 1881-3062
ISSN-L : 1881-3062
Papers
Development of a Neutron Radiography Three-Dimensional Computed Tomography System for Void Fraction Measurement of Boiling Flow in Tight Lattice Rod Bundles
Masatoshi KURETA
Author information
JOURNAL FREE ACCESS

2007 Volume 1 Issue 3 Pages 211-224

Details
Abstract
A neutron radiography three-dimensional computed tomography (NR3DCT) system was developed to visualize the void fraction distribution of boiling flow in tight lattice heated-rod bundles. This paper chiefly reports on the data processing and the error estimation method of NR3DCT. Practical γ-ray noise reduction and image correction techniques were studied to improve the reliability of the experimental data. Using the system and a directly heated 14-rod bundle test section, the behavior of boiling flow in a tight lattice rod bundle was clearly visualized. The effect of each data processing step on the result was also discussed. By this development, the three-dimensional vapor distribution of boiling flow in a heated bundle is made clear, and void fraction databases can be provided for verification of a thermal-hydraulic simulation code.
Content from these authors
© 2007 by The Japan Society of Mechanical Engineers
Previous article Next article
feedback