Journal of Power and Energy Systems
Online ISSN : 1881-3062
ISSN-L : 1881-3062
Papers
Conceptual Design of Divertor Cassette Handling by Remote Handling System of JT-60SA
Takao HAYASHIShinji SAKURAIKei MASAKIHiroshi TAMAIKiyoshi YOSHIDAMakoto MATSUKAWA
Author information
JOURNAL FREE ACCESS

2008 Volume 2 Issue 2 Pages 522-529

Details
Abstract

The JT-60SA aims to contribute and supplement ITER toward demonstration fusion reactor based on tokamak concept. One of the features of JT-60SA is its high power long pulse heating, causing the large annual neutron fluence. Because the expected dose rate at the vacuum vessel (VV) may exceed 1 mSv/hr after 10 years operation and three month cooling, the human access inside the VV is restricted. Therefore a remote handling (RH) system is necessary for the maintenance and repair of in-vessel components. This paper described the RH system of JT-60SA, especially the expansion of the RH rail and exchange of the divertor cassettes. The RH rail is divided into nine and three-point mounting. The nine sections can cover 225 degrees in toroidal direction. A divertor cassette, which is 10 degrees wide in toroidal direction and weighs 500kg itself due to the limitations of port width and handling weight, can be exchanged by heavy weight manipulator (HWM). The HWM brings the divertor cassette to the front of the other RH port, which is used for supporting the rail and/or carrying in and out equipments. Then another RH device receives and brings out the cassette by a pallet installed from outside the VV.

Content from these authors