Journal of Power and Energy Systems
Online ISSN : 1881-3062
ISSN-L : 1881-3062
Papers
Numerical Analysis of Heat Transfer Test of Supercritical Water in a Tube Using the Three-Dimensional Two-Fluid Model Code
Takeharu MISAWAHiroyuki YOSHIDAHidesada TAMAIKazuyuki TAKASE
Author information
JOURNAL FREE ACCESS

2009 Volume 3 Issue 1 Pages 194-203

Details
Abstract

The three-dimensional two-fluid model analysis code ACE-3D is developed in Japan Atomic Energy Agency for the thermal design procedure on two-phase flow thermal-hydraulics of light water-cooled reactors. In order to perform thermal hydraulic analysis of SCWR, ACE-3D is enhanced to supercritical pressure region. As a result, it is confirmed that transient change in subcritical and supercritical pressure region can be simulated smoothly using ACE-3D, that ACE-3D can predict the results of the past heat transfer experiment in the supercritical pressure condition, and that introduction of thermal conductivity effect of the wall restrains fluctuation of wall temperature.

Content from these authors
© 2009 by The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top