Journal of Environmental Conservation Engineering
Online ISSN : 1882-8590
Print ISSN : 0388-9459
ISSN-L : 0388-9459
Study on Simultaneous Removal of Organic Matters and Nitrogen with Aeration Control in Highly Concentrated Activated Sludge Process Using Disk Type UF Membrane
Tsuyoshi IMAIShuguang LUMasao UKITAMasahiko SEKINETakaya HIGUCHIMasayuki FUKAGAWA
Author information
JOURNAL FREE ACCESS

2000 Volume 29 Issue 4 Pages 299-309

Details
Abstract
A study has been made on optimal operating condition capable of carrying out simultaneous removal of organic matters and nitrogen in a highly concentrated activated sludge process using rotary disk type UF membrane as liquid-solid separator.
From the experimental results, the optimal condition for operating time control aeration is deduced to be 30-min., aeration on and 30-min, aeration off, from the aspect of economic advantages such as costs involved in aeration.
The optimal operation in this study was found at ORP centering about 50 to 100mV, with a certain level of fluctuation (±50 to ±75mV) .
Content from these authors
© Society of Environmental Conservation Engineering
Previous article Next article
feedback
Top