Journal of Robotics and Mechatronics
Online ISSN : 1883-8049
Print ISSN : 0915-3942
ISSN-L : 0915-3942
Regular Papers
Improved 3D Human Motion Capture Using Kinect Skeleton and Depth Sensor
Alireza BilesanShunsuke KomizunaiTeppei TsujitaAtsushi Konno
Author information
JOURNAL OPEN ACCESS

2021 Volume 33 Issue 6 Pages 1408-1422

Details
Abstract

Kinect has been utilized as a cost-effective, easy-to-use motion capture sensor using the Kinect skeleton algorithm. However, a limited number of landmarks and inaccuracies in tracking the landmarks’ positions restrict Kinect’s capability. In order to increase the accuracy of motion capturing using Kinect, joint use of the Kinect skeleton algorithm and Kinect-based marker tracking was applied to track the 3D coordinates of multiple landmarks on human. The motion’s kinematic parameters were calculated using the landmarks’ positions by applying the joint constraints and inverse kinematics techniques. The accuracy of the proposed method and OptiTrack (NaturalPoint, Inc., USA) was evaluated in capturing the joint angles of a humanoid (as ground truth) in a walking test. In order to evaluate the accuracy of the proposed method in capturing the kinematic parameters of a human, lower body joint angles of five healthy subjects were extracted using a Kinect, and the results were compared to Perception Neuron (Noitom Ltd., China) and OptiTrack data during ten gait trials. The absolute agreement and consistency between each optical system and the robot data in the robot test and between each motion capture system and OptiTrack data in the human gait test were determined using intraclass correlations coefficients (ICC3). The reproducibility between systems was evaluated using Lin’s concordance correlation coefficient (CCC). The correlation coefficients with 95% confidence intervals (95%CI) were interpreted substantial for both OptiTrack and proposed method (ICC > 0.75 and CCC > 0.95) in humanoid test. The results of the human gait experiments demonstrated the advantage of the proposed method (ICC > 0.75 and RMSE = 1.1460°) over the Kinect skeleton model (ICC < 0.4 and RMSE = 6.5843°).

Content from these authors

This article cannot obtain the latest cited-by information.

© 2021 Fuji Technology Press Ltd.

This article is licensed under a Creative Commons [Attribution-NoDerivatives 4.0 International] license (https://creativecommons.org/licenses/by-nd/4.0/).
The journal is fully Open Access under Creative Commons licenses and all articles are free to access at JRM official website.
https://www.fujipress.jp/jrobomech/rb-about/#https://creativecommons.org/licenses/by-nd
Previous article Next article
feedback
Top