Abstract
Magnetic fluid tuned liquid column damper (MF-TLCD) is a kind of semi-active damper that uses magnetic fluid as its working fluid. An MF-TLCD alters the natural frequency of the magnetic fluid column that forms the resident liquid inside the MF-TLCD by applying a magnetic field. We quantitatively investigated the damping coefficient generated by the flow of magnetic fluid, which is strongly related to the damping performance. Three kind of U-pipes that have each different shape ((1) conventional (2) equipped with an orifice (3) curved fluently) were prepared and single-degree-of-freedom oscillation was performed with each those pipes. Finally, we discussed the effect to the damping performance of MF-TLCD induced by various damping coefficient subjected to magnetic field and configurations of those U-pipes.