2019 Volume 27 Issue 1 Pages 49-54
A Coil for wireless power transmission was manufactured by using of sewing techniques. The sewing methods and electric characteristics were described. The coils were sewn with a cross stitch. The inductance and loss resistance of the sewn coils was measured. It is assumed that the power receiving side coil is attached to biomedical implantable devices. The coupling coefficient between the power receiving side coil and the sewn coil was measured. The maximum coupling coefficient was 0.75. The maximum efficiency of 75.0% was obtained when the coupling coefficient was maximum. Inverter and rectifier were attached the circuit and the load voltage was measured. The maximum load voltage was 4.77 V.