1954 Volume 15 Issue 3-4 Pages 117-118
1. Size of sprayed particles, the velocity of the wind and the distance reached by the particles were observed using the new Mist Blower.
2. Weakness of the velocity of the stream has no relation to revolution and is indicated as follows;
V/V0=0.0363X-1.533
Then V: Wind velocity at measuring point.
V0: Initial wind velocity at nozzle.
X: Distance from nozzle to measuring point.
3. Applying Stokes' law, this formula will be converted into;
X=4.5ηH/ρ1gr2{0.157V00.3948(ηH/ρ1gr2)-0.6052+Vc}
Then X: Arrival distance of particle.
r: Radius of particle.
η: Viscosity coeficient of air.
ρ1: Specific weight of a particle.
H: Height of nozzle from land.
g: Acceleration of gravity.
Vc: Natural wind velocity.