1965 Volume 27 Issue 1 Pages 3-5,10
In this report, the cooling performance of farm air cooled engine which was cooled by the radial fans having six different number of blades was compared, and the following results were obtained.
In this test, it was necessary to be cautioned that the cylinder temperature approached the extremely high value of 185°C at the rated load. The cylinder temperature rose higher han 185°C when cooled by less than eight blades fans.