Jinko Zoki
Online ISSN : 1883-6097
Print ISSN : 0300-0818
ISSN-L : 0300-0818
CLINICAI EXPERIENCE WITH HIGH POROSITY KNITTED GRAGTS IN SURGICAL REPAIR OF THORACIC ANEURYSMS USING FIBRIN GLUE UNDER EXTRACORPOREAL CIRCULATION
H. HIROSES. NAKANOH. MATSUDAR. SHIRAKURAS. NAKATAM. OHTANIT. HIRANAKAN. OHKUBOS. TANS. MIYAGAWAY. NAKAY. KAWASHIMA
Author information
JOURNAL FREE ACCESS

1987 Volume 16 Issue 3 Pages 1449-1452

Details
Abstract
Fibrin glue was used to preseal high porosity knitted Dacron grafts in repair of thoracic aneurysms in sixteen patients under extracorporeal Circulation. Mean duration of extracorporeal circulation was 171 minutes. There were no early and late complications related with this procedure, except one patient, who had bleeding through the presealed graft during surqery. Hepatic dysfunction was found in two of ten patients with use of fibrin glue and in one of ten without its use.
Content from these authors
© The Japanese Society for Artificial Organs
Previous article Next article
feedback