Abstract
For high voltages, large hystereses are usually observed in multi-stack actuators. To cancel it, either
hysteresis modeling or closed loop system can be used. To overcome the limitations of both techniques,
we present here an application of the correlation of the strain and polarization to build a self-sensing
hysteresis cancellation. The advantage of this technique is to remain efficient for various voltage profiles
and don't require additional sensor.