Japanese Journal of Clinical Chemistry
Online ISSN : 2187-4077
Print ISSN : 0370-5633
ISSN-L : 0370-5633
Determination of Mevalonic Acid in Plasma and Urine by Using HPLC
Kazumi GondohShingo ItohYutaka Tsukada
Author information
JOURNAL FREE ACCESS

1995 Volume 24 Issue 2 Pages 89-93

Details
Abstract

A simple HPLC method for determination of mevalonic acid in plasma and urine is described. Mevalonic acid was converted to de-hydromevalonolactone with perchloric acid in ethyl acetate, and the product was detected by UV at 230 nm. The detection limit was 0.8 ng/ml (S/N=4). The recoveries of mevalonolactone in plasma and urine were 95.6-104.0% and 99.4-103.8%, respectively.
This HPLC method is simple and useful for clinical tests compared with conventional radioenzymatic or GC-MS.

Content from these authors
© Japan Society of Clinical Chemistry
Previous article Next article