2026 Volume 7 Issue 3 Pages 452-461
In three-dimensional deformation measurements using a terrestrial laser scanner (TLS), under conditions in which the surface of a test structure reaches high temperatures, such as during a fire resistance test, a refractive-index distribution develops in the air along the optical path between the heated surface and the TLS, causing refraction of the laser beam. Consequently, apparent positional deviations may occur in the acquired point clouds. In this study, a procedure for calculating positional deviations in TLS point clouds was established by numerically analyzing laser beam refraction based on a one-dimensional approximation of the refractive-index distribution along the optical path for fire resistance testing environments with available temperature information. As an application example, the procedure was applied to point clouds of the fire door acquired during a fire resistance test. The calculated correction value increased as the temperature around the fire door increased and tended to become larger as the optical path length from the TLS increased. The maximum correction value obtained in this application was 0.189 mm. Comparison with the overall deformation of the fire door indicated that the influence of the correction on global deformation assessment was limited.