Abstract
The authors investigated the disturbance and backfilling in the area surrounding a segment through grout holes at 40sites. The analytical results of the measured data show that the disturbed area consists of a cavity in which the tail void remains, and a collapsed region caused by over excavation and meandering. In addition, a computational expression for rational amount of backfill grouting according to ground type and strength considering the magnitude of the disturbance is proposed.