Abstract
Pseudo-dynamic tests have been performed with five concrete-filled steel columns and one steel box column in order to investigate the seismic behavior of slender bridge piers. The test results show that concrete-filled steel slender bridge piers do not always cause large residual displacements, but cause large maximum response displacements.