Doboku Gakkai Ronbunshu
Online ISSN : 1882-7187
Print ISSN : 0289-7806
ISSN-L : 0289-7806
A LEAK DETECTION SYSTEM FOR LANDFILL SITE ON DIFFERENCE OF ELECTRIC POTENTIAL, MEASURED BY THE DIFFERENTIAL AMPLIFIER
Ken AraiHitoshi AraiNobuyoshi YamazakiNobuaki Otsuki
Author information
JOURNAL FREE ACCESS

1998 Volume 1998 Issue 602 Pages 75-91

Details
Abstract
The electrical prospection methods like the charged potential method have been applied for leak detection of landfill geomembrane liner. In these methods, leakpoints of liner are detected and located by the distortion of electric potential or resistivity contour lines. But, it is very difficult to detect the leakpoints, because the contour lines are distorted by the shape of the landfil sites and the quality of waste. Authors developed a new method to search the leakpoints without affection of the shape of landfill sites, on measured the difference of electric potential of 2 electrodes at same distance from the current electrode by the differential amplifier. This paper presents the principle of the method and effectiveness of the measuring system.
Content from these authors
© by Japan Society of Civil Engineers
Previous article Next article
feedback