2021 Volume 77 Issue 7 Pages III_329-III_338
Regular chemical cleaning is conducted in drinking water treatment plants(DWTP) to recover flux declining. In the present experiment, we conducted accererated ageing test by soaking PVDF hollow fiber membrane in sodium hypochlorite, which is common cleaning agent in membrane fitration system. In addition to that, we harvested membranes which were used in a DWTP. We compared virgin membrane, used membrane and soaked membrane by assessing surface structure, selectivity, permeability and pore size distribution. Soaked membrane showed less selectivity than virgin membrane and the decline was similar to used membrane. On the other hand, surface structure and pore size distribution were different between used and soaked membrane. Chages in structure can be different between acceralated ageing test and ageing at DWTP.